Underwriters Laboratories Inc.

QMTS2.E95862
Polymeric Materials - Filament-wound Tubing, Industrial Laminates, Vulcanized Fiber, and Materials for Use in Fabricating Recognized Printed Wiring Boards - Component

         

Polymeric Materials - Filament-wound Tubing, Industrial Laminates, Vulcanized Fiber, and Materials for Use in Fabricating Recognized Printed Wiring Boards - Component


 
ETERNAL CHEMICAL CO LTD E95862
578 CHIEN-KUNG RD
KAOHSIUNG, TAIWAN

Mtl
Dsg

ANSI
Type


Col

Min Thk

TI


HWI
UL94
Flame
Class


HAI


HVTR


D-495


CTI
In. (mm) Elec Mech

Industrial laminates, furnished in the form of sheets.

ETL-101 XPC BN 0.028 0.71 130 130 1 94HB 0 4
0.057 1.45 130 130 1 94HB 0 4 7 4
ETL-103 XPC TN 0.028 0.71 130 130 4 HB 4 4
0.057 1.45 130 130 4 HB 3 4 3
ETL-202 FR-1 NC 0.031 0.8 130 130 1 94V-0 3 0 3
FR-1 0.063 1.6 130 130 0 94V-0 0 0 3
ETL-204 FR-1 TN 0.028 0.71 130 130 3 94V-0 3 4 6 0
FR-1 TN 0.057 1.45 130 130 3 94V-0 3 4 6 0
ETL-207 FR-1 Nat. 0.028 0.71 130 130 3 94V-0 3 0 2 0
0.057 1.45 130 130 3 94V-0 3 4 2 0
ETL-XPC-207% FR-1 Nat. 0.028 0.71 130 130 3 94V-0 0 0 5 2
0.057 1.45 130 130 3 94V-0 0 0 2
ETL-301 FR-2 BN 0.028 0.71 75 75 4 94V-0 3 4
0.057 1.45 105 105 4 94V-0 3 4 6 4
ETL-302 FR-2 NC 0.028 0.71 75 75 0 94V-0 0 0
FR-2 NC 0.057 1.45 105 105 0 94V-0 0 0 6 2
ETL-303 FR-2 TN 0.028 0.71 75 75 4 94V-0 3
FR-2 TN 0.057 1.45 105 105 0 94V-0 3 6 3
ETL-304 FR-2 NT 0.028 0.71 75 75 0 94V-0 3 4 0
0.057 1.45 105 105 0 94V-0 3 4 6 0
ETL-307 FR-2 BN 0.028 0.71 75 75 4 94V-0 3 6
FR-2 BN 0.057 1.45 105 105 4 94V-0 3 6 2 4
ETL-401 FR-4 GN 0.031 0.8 130 140 0 94V-0 3 4
0.063 1.6 130 140 0 94V-0 2 4 7 4
ETL-501 CEM-1 YL 0.031 0.8 130 140 3 94V-0 2 4
0.063 1.6 130 140 1 94V-0 2 4 6 3
ETL-502 CEM-1 NC 0.025 0.63 130 140 3 94V-0 2 4
0.055 1.4 130 140 1 94V-0 2 4 6 3
ETL-531 CEM-3 GN 0.031 0.8 130 140 0 94V-0 2 4
0.063 1.6 130 140 0 94V-0 2 4 3
ETL-601 XPC TN 0.02 0.5 130 130 3 94HB 0 0 7 2
0.028 0.71 130 130 2 94HB 0 0 7 2
0.057 1.45 130 130 2 94HB 0 0 7 2
ETL-616 XPC TN 0.031 0.8 130 130 2 94HB 0 4
0.062 1.6 130 130 1 94HB 0 4 7 3
ETL-801 FR-1 TN 0.028 0.71 130 130 0 94V-0 2 0 6 0
0.057 1.45 130 130 0 94V-0 1 0 6 0
Base
Mtl
Min

Clad Cond
Thk

Max
Area
Clad
Mtl
Dsg

ANSI
Type
Thk
In.
(mm)
Min
Mils
(Mics)
Max
Mils
(Mics)
Diam
In.
(mm)
Sold Lts UL94
Flame
Class
Max
Oper
Temp
Temp
C
Time
Sec

Metal clad industrial laminates for use in printed wiring boards, furnished in the form of sheets with cladding on one side only.

ETL-XPC-204 FR-1 0.031 0.67 2.7 1.5 288 12 94V-0 130
-0.78 -17 -68 -38.1
ETL-XPC-207 FR-1 0.028 0.67 2.7 2 260 20 94V-0 130
-0.71 -17 -70 (50.8)#
ETL-FR2-301 FR-2 0.062 1.35 2.7 2 265 13 94V-0 105
-1.57 -35 -70 (50.8)#
0.062 1.35 2.7 2 270 10 94V-0 105
-1.57 -35 -70 (50.8)#
0.062 1.35 2.7 2 280 8 94V-0 105
-1.57 -35 -70 (50.8)#
0.062 1.35 2.7 2 290 6 94V-0 105
-1.57 -35 -70 (50.8)#
0.062 1.35 2.7 2 300 3 94V-0 105
-1.57 -35 -70 (50.8)#
ETL-FR2-307 FR-2 0.028 0.67 2.7 2 260 20 94V-0 75
-0.71 -17 -68 (50.8)#
0.028 0.67 2.7 2 288 12 94V-0 75
-0.71 -17 -68 (50.8)#
0.057 0.67 2.7 2 260 20 94V-0 105
-1.45 -17 -68 (50.8)#
ETL-FR4-401 FR-4 0.031 0.65 3.9 2 280 30 94V-0 130
-0.8 -17.5 -108 -50.8
0.031 0.65 3.9 2 290 20 94V-0 130
-0.8 -17.5 -108 -50.8
0.031 0.65 3.9 2 300 10 94V-0 130
-0.8 -17.5 -108 -50.8
ETL-CMI-501 CEM-1 0.031 0.65 3.9 2 280 30 94V-0 130
-0.8 -17.5 -108 -50.8
0.031 0.65 3.9 2 290 20 94V-0 130
-0.8 -17.5 -108 -50.8
0.031 0.65 3.9 2 300 10 94V-0 130
-0.8 -17.5 -108 -50.8
ETL-CM3-531 CEM-3 0.031 0.65 3.9 2 280 30 94V-0 130
-0.8 -17.5 -108 -50.8
0.031 0.65 3.9 2 290 20 94V-0 130
-0.8 -17.5 -108 -50.8
0.031 0.65 3.9 2 300 10 94V-0 130
-0.8 -17.5 -108 -50.8
ETL-XPC-601 XPC 0.031 0.67 2.7 2 274 20 94HB 130
-0.8 -17 -68 (50.8)#
ETL-XPC-801 FR-1 0.031 0.67 2.7 2 274 20 94V-0 130
-0.78 -17 -68 (50.8)#
ETL-XPC-801 FR-1 0.031 0.67 2.7 0.5 288 12 94V-0 130
-0.78 -17 -68 -12.7

Metal clad industrial laminates for use in printed wiring boards, furnished in the form of sheets, with copper cladding on one or both sides.

ETL-XPC-101 XPC 0.031 1.35 2.7 2 265 13 94HB 130
-0.79 -35 -70 (50.8)#
0.031 1.35 2.7 2 270 9 94HB 130
-0.79 -35 -70 (50.8)#
0.031 1.35 2.7 2 280 7 94HB 130
-0.79 -35 -70 (50.8)#
0.031 1.35 2.7 2 290 5 94HB 130
-0.79 -35 -70 (50.8)#
0.031 1.35 2.7 2 300 2 94HB 130
-0.79 -35 -70 (50.8)#
ETL-XPC-101 XPC 0.062 1.35 2.7 2 270 10 94HB 130
-1.57 -35 -70 (50.8)#
0.062 1.35 2.7 2 280 8 94HB 130
-1.57 -35 -70 (50.8)#
0.062 1.35 2.7 2 290 6 94HB 130
-1.57 -35 -70 (50.8)#
0.062 1.35 2.7 2 300 3 94HB 130
-1.57 -35 -70 (50.8)#
ETL-XPC-202 FR-1 0.031 1.35 2.7 2 @@ @@ 94V-0 130
-0.8 -34 -68 (50.8)#
ETL-XPC-204 FR-1 0.028 1.35 2.7 2 270 10 94V-0 130
-0.71 -34 -68 (50.8)#
FR-1 0.031 0.67 2.7 1.5 274 20 94V-0 105
-0.78 -17 -68 -38.1
ETL-XPC-204 FR-1 0.031 0.67 2.7 2 274 20 94V-0 130
-0.78 -17 -68 (50.8)#
ETL-XPC-204 FR-1 0.031 0.67 2.7 0.5 288 12 94V-0 105
-0.78 -17 -68 -12.7
ETL-XPC-207 FR-1 0.028 0.67 2.7 2 288 12 94V-0 130
-0.71 -17 -70 (50.8)#
ETL-FR2-302 FR-2 0.031 1.35 2.7 2 290 10 94V-0 75
-0.78 -34 -68 (50.8)#
FR-2 0.057 1.35 2.7 2 290 10 94V-0 105
-1.45 -34 -68 (50.8)#
ETL-FR2-303 FR-2 0.028 1.35 2.7 2 270 10 94V-0 75
-0.71 -34 -68 (50.8)#
0.057 1.35 2.7 2 270 10 94V-0 105
-1.45 -34 -68 (50.8)#
ETL-FR2-304 FR-2 0.028 1.35 2.7 2 265 13 94V-0 75
-0.71 -35 -70 -50.8
0.028 1.35 2.7 2 270 10 94V-0 75
-0.71 -35 -70 -50.8
0.028 1.35 2.7 2 290 5 94V-0 75
-0.71 -35 -70 -50.8
0.057 1.35 2.7 2 265 13 94V-0 105
-1.45 -35 -70 -50.8
0.057 1.35 2.7 2 270 10 94V-0 105
-1.45 -35 -70 -50.8
0.057 1.35 2.7 2 290 5 94V-0 105
-1.45 -35 -70 -50.8
ETL-FR2-307 FR2 0.057 0.67 2.7 2 288 12 94V-0 105
-1.45 -17 -68 -50.8
ETL-CEM1-502 CEM-1 0.025 0.67 3.9 2 288 30 94V-0 130
-0.63 -17 -108 -50.8
ETL-XPC-601 XPC 0.028 1.35 2.7 2 260 10 94HB 130
-0.71 -34 -68 -50.8
ETL-XPC-601 XPC 0.028 0.67 2.7 1.5 274 20 94HB 105
-0.71 -17 -68 -38.1
ETL-XPC-616 XPC 0.031 1.35 3.9 2 @ @ 94HB 130
-0.8 -34 -108 -50.8
ETL-XPC-801 FR-1 0.028 1.35 2.7 2 260 10 94V-0 130
-0.71 -34 -68 -50.8
ETL-XPC-801 FR-1 0.031 0.67 2.7 2 274 20 94V-0 105
-0.78 -17 -68 -50.8
ETL-XPC-801 FR-1 0.031 0.67 2.7 0.5 288 12 94V-0 105
-0.78 -17 -68 -12.7

Mtl Dsg

ANSI
Type


Col

Min Thk

TI


HWI
UL94
Flame
Class


HAI


HVTR


D-495


CTI
Unclad Copper Clad In. (mm) Elec Mech

Industrial laminate furnished in sheet form.

ETL-102 ETL-XPC-102 XPC BR 0.031 -0.8 130 130 4 94HB 1
0.062 -1.6 130 130 3 94HB 1 2 2
Base Mtl Clad Cond
Min Thk Max

Clad
Mtl Dsg

ANSI
Type
Thk
In.
(mm)
Min
Mils
(Mics)
Max
Mils
(Mics)
Area
Diam
In. (mm)
Sold Lts UL94
Flame
Class
Max
Oper
Temp
Temp
F (C)
Time
Sec

Metal clad industrial laminates for use in printed wiring boards, furnished in the form of sheets, with copper cladding on one or both sides.

ETL-XPC-102 XPC 0.031 1.35 2.7 2 265 13 94HB 130
-0.8 -35 -70 (50.8)#
0.031 1.35 2.7 2 270 9 94HB 130
-0.8 -35 -70 (50.8)#
0.031 1.35 2.7 2 290 6 94HB 130
-0.8 -35 -70 (50.8)#
0.031 0.67 2.7 0.5 288 12 94HB 105
-0.8 -17 -70 -12.7

Metal clad industrial laminates for use in printed wiring boards, furnished in the form of sheets with cladding on one side only.

ETL-XPC-102 XPC 0.031 0.67 2.7 2 274 20 94HB 130
-0.8 -17 -70 (50.8)#
0.031 0.67 2.7 2
-0.8 -17 -70 (50.8)# 288 12 94HB 130

@ - Solder limits for grade ETL-XPC-616 are 190/5, 270/9 or 290/5.

@@ - Solder limits for grade ETL-XPC-202 are 265/13, 270/10 or 290/5.

# - 2.0 inch (50.8mm) maximum area diameter may be considered representative of larger diameters based upon printed wiring board fabricators limitations.

% - The values shown are for declad material with residual adhesive.


Marking: Company name and material designation on material, container or wrapper.
Last Updated on 2002-05-20

This page and all contents are Copyright © 2005 by Underwriters Laboratories Inc.®

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2005 Underwriters Laboratories Inc.®"